1000ppm sensitivity to detect combustible gases, including natural gas, methane, propane (LPG), diesel, and kerosene, with instant response both audio and visual. Fits in a shirt pocket.
Specifications:
Sensitivity: > 1,000ppm combustible gas (Methane).
Operating Temp: 32° to 104°F (0° to 40° C).
Warm-up: 7-10 seconds.
Response Time: Instantaneous.
Battery: Two AAA.
Power Consumption: DC 20mA.
Battery Life: 3 continuous hours.
Size: 34.9 x 127 x 19.1cm.
Weight: 0.30 lb. (0.14 kg.).
Carbon Monoxide Alarm provides critical protection against the dangers of deadly carbon monoxide and continuously monitors CO levels. It is battery-operated, lightweight and compact.
Features and benefits
• Electro-chemical CO sensor which is highly sensitive for detection
• Continuous monitoring for extra constant safety
• Multi-function LEDs for varying alarm identification
• Test/Reset button to allow regular testing
• Supplied with 2 x AA alkaline batteries
Standards
• EN50291-1:2018
The MSA Altair multi gas monitors incorporate industry-leading XCell sensors which deliver unparalleled performance, increased durability, and delivers enhanced worker safety. The units are designed to notify users of gas monitoring results and provides both audible and visible alarms which include a screen reading and bright LED lights. These notifications are set up to inform both the users and those nearby of the environmental conditions. Green lights inform of safe conditions where red lights notify of dangers. Housed in a thick rubberised casing allows the monitors to survive accidental drops and being IP67 dust and water resistant allows for increased durability and lifetime.
Features and Benefits
• Replaceable lithium batteries provide a long lifetime
• Visual and audible notifications allow for easy reading and alerts to both the user and those nearby
• Thick rubberised casing with IP67 dust and water resistance increases durability and lifetime
It is important to regularly check for possible electromagnetic leaks from Microwave ovens. Excessive leakage can be a problem and of particular danger to expectant mothers. This Faithfull detector can be used to verify any leak from Microwave ovens and other sources within a few minutes. The detector's analogue display will clearly show if an electromagnetic field leak is present. The Green sector indicates that the product is safe, the Red sector warns that a leak is present which could be harmful to humans. The detector may also be used to check other items that generate an electromagnetic field such as Mobile Phones and Cameras. Features Analogue needle indicator. Easy read SAFE and CAUTION warning. Compact and easy-to-use. Frequency range 3MHz to 3GHz. No battery required. Use on microwave ovens, mobile phone and cameras. Applications This detector may be used to Detect leaks from electrical items generating an electromagnetic field when in operation. The frequency range covered by this detector is 3MHz to 3GHz. Specification Frequency Range 3MHz to 3GHz. Working Temperature 0C to 40C. Size 45 x 100 x 22mm. Weight Approx. 38g.
The Detectagas CO alarm includes a full kit bag with lid, and a full sensor test to ensure your alarm still works.
SAFE-TECH Standalone Carbon Monoxide Detector places the highest priority on safety. Also, this alarm meets the British standard for CO Alarms, BS EN 50291-1:2018. Additionally, this alarm is tested to meet UKCA and CE standards.
This detector has an advanced electrochemical sensor. Therefore, it detects even the smallest rise in CO levels, giving a quick response to potential CO poisoning. Also, this detector has a 10 Year tamper-proof battery. Lasting for 10 years and guaranteeing continuous protection.
This Standalone Carbon Monoxide Detector is compliant with the latest Scottish Legislation. Making it Suitable for any room that has a carbon-burning fuel appliance. CO alarm density is as follows :
50ppm alarm does not activate, within 120 minutes.
50-100ppm, an alarm within 80 minutes.
100-300ppm, an alarm within 30 minutes.
300ppm, an alarm within 50 seconds.
* Battery life may vary based on configuration, application usage, and features.
* We try to get you the best quality photo and size. All pictures shown here are for illustration purposes only. Actual product size and colour may vary slightly.
For further instructions and Videos, please go here
High-performance electrochemical CO sensor. Long standby time low power consumption 10-year battery life.
Avoid the dangers of CO poisoning. Battery operated alarm which will emit an 85dB sound when dangerous levels of CO are detected.
Mp Nova 6 Dt X91 Plus 2 Dayturn 3 Years Dayone In
Note: Image is for illustrative purposes only and may differ from the actual product.
SAFE-TECH Interlinked Carbon Monoxide Detector places the highest priority on safety. Also, this alarm meets the British standard for CO Alarms, BS EN 50291-1:2018. Additionally, this alarm is tested to meet UKCA and CE standards.
This detector has an advanced electrochemical sensor. Therefore, it detects even the smallest rise in CO levels, giving a quick response to potential CO poisoning. Also, this detector has a 10 Year tamper-proof battery. Lasting for 10 years and guaranteeing continuous protection.
This Interlinked Carbon Monoxide Detector is compliant with the latest Scottish Legislation. Making it Suitable for any room that has a carbon-burning fuel appliance. CO alarm density is as follows :
50ppm alarm does not activate, within 120 minutes.
50-100ppm, an alarm within 80 minutes.
100-300ppm, an alarm within 30 minutes.
300ppm, an alarm within 50 seconds.
* Battery life may vary based on configuration, application usage, and features.
* We try to get you the best quality photo and size. All pictures shown here are for illustration purposes only. Actual product size and colour may vary slightly.
For further instructions and Videos, please go here
Daewoo Carbon Monoxide Digital Alarm 102391
Due to geographical locations we are unable to deliver to: Isle of Wight, Isle of Man and Ireland.
TIMCO Air & Gas Leak Detector is a professional formulation, designed to quickly and reliably detect the smallest leak in pressurised systems. Reacts instantly upon contact with gas and air pressure, forming a stream of bubbles to identify the leak. Ideal for refrigeration units, air conditioning systems, exhausts, pipes, valves, screw connectors, welded seams and more.
Please Note : Due to geographical locations we are unable to deliver to Highlands
Single valve series 70 SAFE AIR electro-pneumatic 1/4'' 3/2 monostable with spring mechanical NC, cable 0.3 m, M8
Specifications:
EAN code: 8024986508611
Short description: Single70 elpn 1/4'' 3/2 cable 2 m ATEX
Quantity per package: 0
Minimum order quantity: 0
Unit of measure: items
Valves -
Functional denomination
Valve electro-pneumatic NC monostable
Max temperature (°C) 45
Min temperature (°C) -10
Product's series Valves series 70 SAFE AIR
Type Electro-pneumatic
Single valves ISO 2 5599/1 SAFE AIR solenoid/pneumatic 5/2 solenoid/pneumatic mechanical spring, cable 2 m ATEX Specifications: EAN code: 8024986908060 Short description: Single ISO 2 elpn 5/2 cable 2 m ATEX Quantity per package: 0 Minimum order quantity: 0 Unit of measure: items Valves - Flow-rate 2,700.00 l/min Flow-rate at 6.3 bar DP 1 bar (Nl/min) 2700 Functional denomination valves Max input pressure N 10.00 bar Max temperature (°C) 60 Min Input Pressure -0.99 bar Min temperature (°C) -10 PL - ISO EN 1384 Suitable for use in safety circuits up to PL=c Product's series SAFE AIR series Reference norms ISO 5599/1 Type Electro-pneumatic Voltage 24VDC - 24VAC - 110VAC - 220VAC Way scheme 5/2
Single valves ISO 2 5599/1 SAFE AIR solenoid/pneumatic 5/2 electric pilot-assisted mechanical spring, cable 2 m ATEX Specifications: EAN code: 8024986908039 Short description: Single ISO 2 elpn 5/2 servopil. cable 2 m ATEX Quantity per package: 0 Minimum order quantity: 0 Unit of measure: items Valves - Flow-rate 2,700.00 l/min Flow-rate at 6.3 bar DP 1 bar (Nl/min) 2700 Functional denomination valves Max input pressure N 10.00 bar Max temperature (°C) 60 Min Input Pressur 2.50 bar Min temperature (°C) -10 PL - ISO EN 1384 Suitable for use in safety circuits up to PL=c Product's series SAFE AIR series Reference norms ISO 5599/1 Type Electro-pneumatic Voltage 24VDC - 24VAC - 110VAC - 220VAC Way scheme 5/2
Single valves ISO 1 5599/1 SAFE AIR solenoid/pneumatic 5/2 solenoid/pneumatic mechanical spring, cable 2 m ATEX Specifications: EAN code: 8024986905113 Short description: Single ISO 1 elpn 5/2 cable 2 m ATEX Quantity per package: 0 Minimum order quantity: 0 Unit of measure: items Valves - Flow-rate 1,100.00 l/min Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1100 Functional denomination valves Max input pressure N 10.00 bar Max temperature (°C) 60 Min Input Pressur 2.50 bar Min temperature (°C) -10 PL - ISO EN 1384 Suitable for use in safety circuits up to PL=c Product's series SAFE AIR series Reference norms ISO 5599/1 Type Electro-pneumatic Voltage 24VDC - 24VAC - 110VAC - 220VAC Way scheme 5/2
Double valves ISO 1 5599/1 SAFE AIR solenoid/pneumatic 5/2 solenoid/pneumatic mechanical spring, cable 2.5 m, 3 wires
Specifications:
EAN code: 8024986914146
Short description: Double ISO1 elpn 5/2 cable 2.5 m, 3w
Quantity per package: 0
Minimum order quantity: 0
Unit of measure: items
Valves -
Flow-rate 1,050.00 l/min
Flow-rate at 6.3 bar DP 1 bar (Nl/min) 1050
Functional denomination valves
Max input pressure N 10.00 bar
Max temperature (°C) 60
Min Input Pressure 2.50 bar
Min temperature (°C) -10
PL - ISO EN 1384 Suitable for use in safety circuits up to PL=e
Product's series SAFE AIR series
Type Electro-pneumatic
Voltage 24VDC - 24VAC - 110VAC - 220VAC
Way scheme double 5/2
State of the Art Monitor Design
Simple, cost-effective and convenient
High sample capacity for sampling a broad range of organic vapours
Easy to use. Just clip the monitor to shirt lapel, collar, or pocket
Unobtrusive. Monitors are small and lightweight and will not interfere with employee activities
Documentation for industrial hygienists and IH labs available upon request
A valid method for air sampling and analysis of many organic vapours
Suggested Applications
The MSA Altair maintenance-free single gas monitors are available in a variety of gas monitor models. The units are designed to notify users of gas monitoring results and provides both audible and visible alarms which include a screen reading and bright LED lights. These notifications are set up to inform both the users and those nearby of the environmental conditions. The units feature the patented MSA-built button cell toxic gas sensors which utilise a stainless steel construction that virtually eliminates sensor leakage. Housed in a thick rubberised casing allows the monitors to survive accidental drops and being IP67 dust and water resistant allows for increased durability and lifetime.
Features and Benefits
• Maintenance-free monitors with long lasting Lithium batteries allow for quick and easy set up for use
• Visual and audible notifications allow for easy reading and alerts to both the user and those nearby
• Thick rubberised casing with IP67 dust and water resistance increases durability and lifetime
The Galaxy GX2 allows you to calibrate and bump test your Altair Gas Detectors simply and efficiently. These systems work for Altair 4/4X, Altair 5/5X, Altair Pro. These configurations support 4 valves allowing calibration up to 4 cylinders. The Galaxy GX2 provides high performance with the option to be used as part of a fleet of calibration systems.
Features and Benefits
• Colour touch screen display provides an easy to use and intuitive navigation system that allows easy usage of the system.
• MSA link software transfers records to and from PC for data logging
Note
The Smart Electronic cylinder holder will be required for use with these systems.
The Altair 4X charger docks allow quick and easy charging of the MSA Altiar 4X with either a cradle for a single instrument or a multi-unit charger that can charge up to 4 instruments at a time. The cradle allows for constant visibility so it can be found at a certain location in the office. The cradle also allows for a quick pick up and go design.
Features and Benefits:
• Charging cradle allows for easy location and handling of a single instrument and allows easy charging
• Multi-unit charger allows charging of up to 4 instruments in one easy charger
The MSA Four Gas Can is a mixture of gas that is used to calibrate the MSA Altair 4X and 5X multi gas detectors. It contains the appropriate amount of each gas to correctly calibrate the sensors. Having 58 litres of gas ensures there is enough gas for plenty of calibrations.
The gas ratios are as following:
1.45% Methane (CH4)
60ppm Carbon Monoxide (CO)
20ppm Hydrogen Sulphide (H2S)
15% Oxygen (O2)
Features and Benefits
• Premixed gas ensure long use time and accurate calibration of MSA Altiar 4X/5X gas monitors
• 58 litres of has ensures there is enough gas for plenty of calibrations
Gas Flow regulators are required to ensure you get the required flow and calibration of gas for the applications required. due to the cost effective design of the diffusion based MSA gas detectors, you are able to use a 0.25lpm flow rate compared to the 0.5lpm market standard. Being made of nickel plated polished aluminium, this regulator is hardy and durable.
Features and Benefits
• Low flow rate allows less use of calibrating gases when calibrating MSA Gas detectors.
• Nickel plated polished aluminium construction creates a hardy and durable regulator
This is a replacement Battery pack or the Alrtair 2X Gas monitor. It can drastically cut costs of your gas detection requirements by extending the lifetime of your already purchased Altair 2X gas monitor. This comes as a pack of 8 so there are plenty of replacements available.
Features and Benefits
• New replacement batteries extend the lifetime of your current gas monitors
• Pack of 8 so there are plenty of replacement batteries for your monitors
Note
It is recommended that a professional carries out this replacement to ensure correct installation.
The Argweld® PurgEye® 1500 Site IP68 Weld Purge Monitor® is a specialised instrument used in welding processes to monitor and control the oxygen levels in the vicinity of the weld. Designed for rugged and demanding environments, it is certified to IP68, which ensures its resistance to water and dust ingress, making it suitable for both above-ground and underwater applications. The PurgEye® 1500 Site IP68 utilises advanced sensor technology to accurately measure oxygen levels as low as 10 parts per million (ppm) , enabling precise control of the purging process to create high-quality, defect-free welds in stainless steel, titanium, and other reactive metals. Its robust construction, user-friendly interface, and durable battery life make it an essential tool for welders working in challenging conditions where maintaining oxygen-free environments is critical.
Benefits
Accurate monitoring and control of oxygen levels during welding processes
Certified to IP68, ensuring resistance to water and dust ingress
Suitable for both above-ground and underwater applications
Advanced sensor technology for precise measurement of oxygen levels from 1000ppm to 1 ppm
Enables precise control of the purging process for high-quality, defect-free welds
Robust construction for durability in rugged environments
User-friendly interface for easy operation
Long battery life for extended use in the field as well as mains-powered.
What's In The Box
PurgeNet™ Smart Cable for transferring Weld Purge Data
PurgeLog™ Data Logging Software (USB Data Stick)
Sample tube set with filter
Sturdy protective storage carrying and presentation case (a spare/replacement case is available for purchase)
Calibration Certificate (valid for 12 months)
User Instruction Manual
Mains power lead or cable with international plug adaptors
FAQs
1. What is the intended application for the Argweld® PurgEye® Site Weld Purge Monitor®?
The PurgEye® Site has been developed for use in extreme conditions such as might be found on a construction site. It is build into a robust, virtually indestructible case.
For extreme weld quality control in aerospace, semiconductor, pharmaceutical, vacuum, biotech, food and drinks industries, petrochemical, oil and gas and all industries where pristine oxide free welds have to be achieved.
Also, applications demanding extremely accurate readings from atmosphere right down to 10 parts per million (ppm) , such as welds made in titanium, duplex, nickel alloys and high specification stainless steels.
2. Does the Argweld® PurgEye® Site have a pump?
Yes, there is an integral electro-mechanical pump.
3. What sort of sensor is used in the Argweld® PurgEye® Site?
The PurgEye® Site uses a solid state long life sensor of a unique design with a faster response time and greater stability of readings than other monitors.
4. My Company needs a calibration certificate once a year for all instruments. How do I obtain one?
At present Huntingdon Fusion Techniques have calibration facilities in the UK, USA, Singapore and Norway. As time goes by they are planning to set up others. Once your instrument has been sent, it will be recalibrated and returned to you with a certificate within a few days.
5. Is the Argweld® PurgEye® Site Weld Purge Monitor® sensitive to electrical high frequency disturbances?
Each instrument has shielding to prevent most forms of interference. Quality control test and inspection criteria are designed to account for as many variables as possible.
6. I need to detect oxygen level in pipes preheated to 300˚C (572˚F) Can I use the Argweld® PurgEye® Site under these conditions?
The Argweld® PurgEye® Weld Purge Monitors® should not be exposed to gas at a temperature above 50˚C (122˚F) .
Please contact us for information about exhaust purge gas cooling methods.
7. How safe is the monitor if I use it in rain or dust storms or if I drop it from a height?
The case when sealed offers IP68 protection and when open it has IP65 protection.
If the case is dropped from a great height it is unlikely that the monitor will suffer any damage.
8. Can Weld Purge Monitors® only be used when purging with argon?
The PurgEye® Weld Purge Monitors® measure the oxygen level within any gas, not only inert gases. They can be used to monitor the oxygen level when using inert gases such as argon and helium and also non-inert gases including nitrogen and nitrogen/hydrogen mixes.
9. What is PurgeNet™?
PurgeNet™controls the welding power sources such as orbital welders and any other automatic welding systems to switch on and off according to oxygen levels, transferring data easily with the ability to link to external devices.
Introducing the Aquasol POM-100B High Purity Oxygen Monitor, the ultimate tool for ensuring precise oxygen concentration measurements in your welding applications. This handheld, rechargeable device boasts an internal pump and Bluetooth connectivity, making it ideal for remote monitoring and data recording. With its 0.01% resolution and Intelligent Colour Notification System, you can rest assured that your welds will be free from oxidation, discoloration, and coking.
Features
Measures oxygen concentration with 0.01% resolution
Bluetooth connectivity for real-time monitoring and data recording
Intelligent Colour Notification System for quick visual oxygen level checks
Alarm limits can be customised to operator preferences
Rechargeable battery for extended use
Built-in dust filter
Application
High purity welding
Ultra-high purity stainless steel welding
Other high alloy metal welding
Purged tubing monitoring
Real-time Operation via Android, iOS and Windows App
BLE transmitting device allows the oxygen monitor to send the oxygen readings wirelessly to any BLE device (i.e. Smartphone/Laptop) .
Instructions
Set Up
1. Attach the Polyurethane Extension Tubing with Female Quick Connect Fitting to the Male Quick Connect Fitting on the top of POM-100B
2. Pull gently to ensure the connection is securely in place. The tubing can easily be removed with the push of a button, no tools are necessary
Connecting to Bluetooth
1. Open App Store (iPhone App Store for iPhone, Google Play App Store for Android, Microsoft Store for Windows) on your Smartphone/Laptop
2. Search for “POM CONNECT” App by Aquasol Corporation
3. Install the “POM CONNECT” App
Set Language
1. Press the “MENU/ENTER” Button
2. Select “Languages” and press the “MENU/ENTER” button
3. Using the “UP/DOWN” arrow buttons, scroll and choose the desired language (English, German, Spanish and Portuguese)
4. Once the language is highlighted, press the “MENU/ENTER” button
Set Alarm
1. Press the “MENU/ENTER” button
2. Using the “UP/DOWN” arrow buttons, select “Set Alarm Limits”. Press the “MENU/ENTER” button
3. The Alarm Limits are used for the Intelligent Color Notification System
4. Press the “MENU/ENTER” button to confirm the limit values
5. Press the “BACK” button to return to the “MAIN MENU”
6. Red indicates that the current measurement is greater than the “Upper Alarm Limit”
7. Yellow indicates that the current measurement is between the “Upper Alarm Limit” and “Lower Alarm Limit”
8. Green indicates that the current measurement is lower than the “Lower Alarm Limit”
Novar ED&S TOOL LIGHTSPOT INFRA-RED PROGRAMMING Next Gen Commissioning Tools QSUB
Novar ED&S LOCKRING LIGHTSPOT FLUSH Next Gen Accessories LOCKRING
Novar ED&S CONTROLLER LIGHTSPOT INFRA-RED USER Next Gen Commissioning Tools QCUB
Collect and separately analyse ethylene oxide in the workplace environment
Accuracy of +/-25%, at a 95% confidence level for many workplace contaminants
Lightweight
Can be stored for up to 18 months
Analysis not included
Wide variety of industrial and laboratorial environments
Suggested Applications
State of the Art Monitor Design
Simple, cost-effective and convenient
A valid method for air sampling and analysis of formaldehyde and certain other aldehydes
Easy to use. Just clip the monitor to shirt lapel, collar, or pocket
Unobtrusive. Monitors are small and lightweight and will not interfere with employee activities
Documentation for industrial hygienists and IH labs available upon request
Analysis is not included
Suggested Applications
State of the Art Monitor Design
Simple, cost-effective and convenient
Highest diffusive sampling rate available for monitoring low contaminant levels and STEL sampling
Easy to use. Just clip the monitor to shirt lapel, collar, or pocket
Unobtrusive. Monitors are small and lightweight and will not interfere with employee activities
Documentation for industrial hygienists and IH labs available upon request
A valid method for air sampling and analysis of low level and short-term monitoring
Suggested Applications
K7L-AT50-KIT (576223) Leakage Sensor - OT-FESTO065518
K7L-AT50 (8044740) Leakage Sensor - OT-FESTO069677
SOPA-CM4H-R1-HQ6-PNLK-A-M12 (8093825) Air Gap Sensor - OT-FESTO085607